20200220
Home > Sensor Module > Temperature Module > AC 110V-220V Temperature Hmidity Controller Sensor Module for Cooling Heating Device

AC 110V-220V Temperature Hmidity Controller Sensor Module for Cooling Heating Device

GY16853
5 9
$6.99 $5.03
Contact us for wholesale price
Time Remaining:
- OR - Add to Wish List
1.Description:
  XH-M453 is a temperature and humidity controller.Adopting single-chip microcomputer control system, integrated temperature sensor and imported integrated sensor, more accurate temperature and humidity measurement.Relay control dual output, it can control temperature and humidity at the same time.Commonly used for anti-condensation protection and environmental protection of high and low voltage switch boxes, terminal boxes and box-type transformers.
 
2.Feature:
  1>.Digital dispiay
  2>.High precision
  3>.Product support control temperature and humidity
  4>.Dual output
  5>.Responsive
  6>.Embedded installation
  7>.Accurate temperature and humidity control
 
3.Parameter:
  1>.Model:XH-M453
  2>.Product Name:Temperature And Humidity Controller
  3>.Input voltage:AC 110V~220V 
  4>.Test Temperature:-20℃~60℃
  5>.Moisture measuring range:0%~100%RH
  6>.Measurement Accuracy:0.1℃
  7>.Humidity accuracy:0.2%
  8>.Output type:Relay output
  9>.Output Current:0A~10A
  10>.Size:105.5*70*39mm
  11>.Sensor length:90cm
 
4.Setting Instructions
  1>.Stop Temperature Setting:Short press SET,when the red screen number starts to flash, then press UP/DOWN button to adjust the stop temperature value.Wait 10 seconds after the setting is completed, the system automatically saves the data.
  2>.Heating or cooling mode setting:Long press UP Button,when C-0 is displayed on the red screen, press the SET button to enter the C-0 mode setting.Then press the UP/DOWN button to switch between blue screen L and H. L stands for heating and H stands for cooling.(Note:When the blue screen is L, the temperature control load you connect must be a heating device.When the blue screen is H, the temperature control load you connect must be a cooling device)Wait 10 seconds after the setting is completed, the system automatically saves the data.
  3>.Temperature difference setting:Long press the UP Button,when C-0 is displayed on the red screen, press the UP/DOWN button to switch to C-1 temperature difference setting,then press the SET button to enter the temperature difference setting.Then press the UP/DOWN button to adjust the set temperature difference.Wait 10 seconds after the setting is completed, the system automatically saves the data.(If the stop temperature is set to 35℃, the mode is set to L heating mode, and the temperature difference is set to 5℃, the start temperature is 30℃, and the temperature control range is between 30℃ and 35℃.In contrast if the mode is set to H cooling mode, the starting temperature is 40℃ and the temperature control range is between 35℃ and 40℃)
  4>.Temperature Correction:Press the UP Button,when C-0 is displayed on the red screen, press the UP/DOWN button to switch to C-2 temperature calibration setting,then press the SET button to enter the temperature calibration setting.Then press the UP/DOWN button to adjust the set temperature difference.If the actual temperature is 28℃ and the detection temperature of the probe is 28.2℃, then the correction difference can be set to -0.2; if the detection temperature is low, then the correction value can be increased.Wait 10 seconds after the setting is completed, the system automatically saves the data.
  5>.Temperature parameter code table:
    5.1>.C-0 is Mode Setting,L means heating and H means cooling,Its default parameters are L heating mode.
    5.2>.C-1 is Temperature Difference,the setting range is 0.1℃~50℃,Its default parameters are 2.0℃.
    5.3>.C-2 is Temperature Calibration,the setting range is -10℃ and 10℃,Its default parameters are 0.0℃.
  6>.Stop temperature setting:Press the SET Button, the red screen numbers start flashing,then press the SET Button to switch to the blue screen digital flashing,then press UP/DOWN Button to adjust the stop humidity value.Wait 10 seconds after the setting is completed, the system automatically saves the data.
  7>.Humidification or dehumidification mode setting:Long press UP Button,when H-0 is displayed on the red screen, press the SET button to enter the H-0 mode setting.Then press the UP/DOWN button to switch between blue screen L and H.L stands for humidification and H stands for dehumidification.(Note:When the blue screen is L, the humidity control load you connect must be a humidification equipment.When the blue screen is H, the temperature control load you connect must be a dehumidification equipment)Wait 10 seconds after the setting is completed, the system automatically saves the data.
  8>.Temperature and humidity difference setting:Long press the UP Button,when H-0 is displayed on the red screen, press the UP/DOWN button to switch to H-1 temperature and humidity difference setting,then press the SET button to enter the temperature and humidity difference setting.Then press the UP/DOWN button to adjust the set temperature difference.Wait 10 seconds after the setting is completed, the system automatically saves the data.(If the stop humidity is set to 50%RH, the mode is set to L humidification equipment, and the humidity difference is set to 5%RH, the start humidity is 45%RH, and the humidity control range is between 45%RH and 50%RH.In contrast if the mode is set to H dehumidification equipment, the starting humidity is 55% and the humidity control range is between 50%RH and 55%RH)
  9>.Humidity Correction:Press the UP Button,when H-0 is displayed on the red screen, press the UP/DOWN button to switch to H-2 humidity calibration setting,then press the SET button to enter the humidity calibration setting.Then press the UP/DOWN button to adjust the set humidity difference.If the actual humidity is 55%RH and the detection humidity of the probe is 56.3%RH, then the correction difference can be set to -0.2; if the detection humidity is low, then the correction value can be increased.Wait 10 seconds after the setting is completed, the system automatically saves the data.
  10>.Humidity parameter code table:
    5.1>.H-0 is Mode Setting,L means humidification and H dehumidification cooling,Its default parameters are L humidification mode.
    5.2>.H-1 is Humidity Difference,the setting range is 0.1%RH~50%RH,Its default parameters are 10%RH.
    5.3>.H-2 is Humidity Calibration,the setting range is -10%RH and 10%RH,Its default parameters are 0.0%RH.
  11>.Reset:Simultaneously press and hold the UP and DOWN Button for 5 seconds. When the screen displays "888", the factory reset is complete.
 
5.Application Examples:
Setting temperature is 38℃~38.3℃, humidity is between 75%RH ~ 80%RH.
  1>.Temperature setting:Set stop temperature to 38.3℃, temperature control mode C-0 to L heating mode, hysteresis setting C-1 to 0.3℃.
  2>.Humidity setting:Set stop humidity to 80%RH, humidity control mode H-0 to L humidification mode, and hysteresis setting H-1 to 5%RH
 
6.Precautions:
  1>.Do not connect the temperature and humidity control output terminals incorrectly.
  2>.No distinction between neutral and live wires when AC220V power supply.
  3>.The maximum current of the output of the controller is 10V, please do not use it in overload, the overload will damage the controller.
  4>.When the displayed temperature and humidity are different from the actual value, you can enter the calibration mode, and change the calibration value to the actual value.
  5>.When the screen displays "LLL", the sensor is faulty. Check whether the sensor wire is disconnected or the sensor plug is not finished properly.If it cannot be solved, please replace the sensor.
 
7.Package:
  1>.1pcs AC 110V~220V Temperature and Humidity Controller;
  2>.1pcs Temperature and Humidity Sensor
  3>.2pcs Screws;
  4>.1pcs Button Film.
 
There are currently no product reviews.

First we should say that ICStation doesn't accept any form of pay on delivery.Items used to be shipped after receiving the order info and payment.

1) Paypal Payment

PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account). 



We are PayPal Verified 

 

2) West Union


 

We know that some of you do not have the Paypal account. 

But please take it easy. You can use West Union payment method.
Learn more at West Union at www.westernunion.com.
 
For the receiver info, please contact us at orders@icstation.com.
 
3) Bank Transfer / Wire Transfer / T/T
 

Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$500. The bank will charge about US$60 for the transfer fee if we do the payment in these ways. 

For other payment method, please contact us at orders@icstation.com for more details.

1. Hongkong / Sinapore Airmail

(1) Due to the high risk of package lost recently, we have to stop using the free shipping way these days. Hope for your kind understanding! And the $3 is for tracking number and delivery insurance ^0^ Enjoy order from us. 

Free Shipping for all orders over $20 ^0^ (with free tracking number and delivery insurance fee)

(2) Shipping time 
Shipping time is 7-20 business days to most of countries; please view below table for exactly shipping time to your location. 

7-15 working days to: Most of Asia countries
10-16 working days to: USA , Canada , Australia , UK , Most of Europe countries
13-20 working days to: Germany , Russia
18-25 working days to: France , Italy , Spain , South Africa
20-45 working days to: Brazil , Most of South America countries

2. EMS/DHL/UPS Express

(1)Shipping Fee: Free for the order which meet the following requirements
Total price of the order >= 200USD or Total weight of the order >= 2.2KG

When the order meets to one of the above requirement, it will be shipped for FREE via EMS/DHL/UPS Express to below country. 
Asia: Japan , South Korea , Mongolia . Malaysia , Singapore , Thailand , Vietnam , Cambodia , Indonesia , Philippines 
Oceania: Australia , New Zealand , Papua New Guinea 
Europe& America: Belgium, Britain, Denmark, Finland, Greece, Ireland, Italy, Luxembourg, Malta, Norway, Portugal, Switzerland, Germany, Sweden, France, Spain, USA, Austria, Canada
Note: Shipping Fee to other countries, please contact orders@ICStation.com

(2) Shipping Time
Shipping time is 3-5 working day (about 1 week) to most of countries. 

Because the package would be returned to the sender if it had not been signed by the receiver in 2-3 day (DHL) or 1 week (EMS,) or 2 weeks (Registered Email), please pay attention to the arriving time of the package. 

Note:

1) APO and PO Box Addresses

We strongly recommend that you provide a physical address for order delivery. 
Because that DHL and FedEx are unable to deliver items to APO or PO BOX addresses. 
 
2) Contact Phone Number
Receivers' contact phone number is required by express shipping agency for the package delivery. Please provide us with your latest phone number.


3. Note
1) Delivery Time of mixed orders with items in different Shipping Status should be calculated using the longest estimate times listed. 
2) Chinese Holiday Reminder: During annual Chinese holidays, services from certain suppliers and carriers may be affected, and delivery for orders placed around the following times may be delayed by 3 - 7 days: Chinese New Year; Chinese National Day,etc. 
3) Once your order is shipped, you will receive an email notification from icstation.com
4) Track the order which with tracking number via below links:

Registered Airmail: www.17track.net/en

Your Recent History

AC 110V-220V Temperature Hmidity Controller Sensor Module for Cooling Heating Device
$5.03
$6.99
29