DC 12V Digital Temperature Controller Module Switch Temp Control Board -9~99 Celsius with Waterproof NTC Sensor Probe
$4.38$6.2530% (only 0 pcs )
00d : 00h : 00m : 00s
Item ID: 12455
Product Details
Parameter:
Parameter | Value |
Temperature Measurement Range | -9~99 Celsius |
Control Precision | 1 Celsius |
Refresh Frequency | 0.5s |
Operating Temperature | -10~60 Celsius |
Operating Humidity | 20%-85% |
Measurement Input | NTC Waterproof Sensor |
Measurement Precision | 1 Celsius |
Setting Value | -9~99 Celsius |
Input Power | DC 9-15V |
Size | 78*51mm |
Output | Relay Output (220V 10A/12V 10A ) |
Features:
1>. Adopt high-speed MCU, accurate intelligent control
2>. Three vision window display
3>. Simple setting, easy to operate
4>. Wide setting range of -9~99 Celsius
5>. Widely applied to room temperature control, water temperature control, incubators etc
Using Method:
Connect the power supply and device, then it can offer power to the controller; and it will display measured temperature in this time, users can set START to STOP according to their needs
The temperature controller output is 10A relay, it can satisfy various high power loads; after connect the circuit, it can supply power for the controller
START Indicator And Digital Tube Introduction
START Indicator: START (the right side) indicator lamp is on, it means the relay and device starts operating
STOP Indicator: STOP (the left side) indicator lamp is on, it means the relay is disconnected and the device stops operating
Digital Tube: the red digital tube display is measured temperature (left green digital tube is setting start temperature; right green digital tube is setting stop temperature)
Key:
Start: “▲▼” set start temperature
Stop: “▲▼”set stop temperature
High-Temperature Start- refrigeration mode:
When the setting start temperature>stop temperature, detection temperature>=start temperature, the relay will operate, and refrigeration device will operate; when detection temperature <=stop temperature, the relay will be disconnected and the refrigeration device will stop operating. For example, set start temperature is 30 Celsius, stop temperature is 25 Celsius, when the detection temperature is no lower than 30 Celsius, the relay will operate and the START indicator lamp (red) will be on; when the detection temperature is no higher than 25 Celsius, the relay will be disconnected and the STOP indicator lamp (red) will be on
Low Temperature Start-Heating Mode:
When the setting start temperature<stop temperature, detection temperature<=start temperature, the relay will operate, and refrigeration device will operate; when detection temperature >=stop temperature, the relay will be disconnected and the refrigeration device will stop operating. For example, set start temperature is 25 Celsius, stop temperature is 30 Celsius, when the detection temperature is no higher than 25 Celsius, the relay will operate and the START indicator lamp (red) will be on; when the detection temperature is no lower than 30 Celsius, the relay will be disconnected and the STOP indicator lamp (red) will be on
Pin Definition:


.jpg)
.jpg)
Module Size:

Tested by ICStation's Outstanding Partner LearningZone:





Learn More Details in the Video: