• DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display
  • DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display

DC Electronic Load Tester Battery Capacity 35W 5A Adjustable Constant Current Aging Resistor Discharger LCD Voltage Current Power Display

$22.99
Quantity5+10+30+
Price$15.85$15.60$14.99
Item ID: 13413

Product Details

1.Description:
The FZ35 5A 35W Electronic Load Tester is an industrial-grade, long-life device that is equipped with a fast-rotating long-life ball fan, making it ideal for continuous discharging and long-period discharge or aging tests for factory products. It can be used to test the output current capability of chargers, batch aging tests for chargers, and battery load capacity.
 
2.Features:
    1>.With outer casing
    2>.LCD high definition display
    3>.Support UART
    4>.High precision 0.01A
    5>.Support over-voltage protection
    6>.Support over-current protection
    7>.Support under-voltage protection
    8>.Support over temperature protection
    9>.Multiple parameters are displayed simultaneously
    10>.Automatically count working hours
 
3.Parameters:
    1>.Product name: FZ35 5A 35W Electronic Load Tester
    2>.Model: FZ35
    3>.Work voltage: DC 5.0V-30V
    4>.Rated load voltage: DC 1.5V-25V
    5>.Rated load current: 5A
    6>.Power: 35W
    7>.Current accuracy:1%
    8>.Voltage accuracy:0.5%
    9>.Over voltage protection: Default 25.2V(Adjustable)
    10>.Over current protection: Default 5.10A(Adjustable)
    11>.Over power protection: Default 35.5W(Adjustable)
    12>.Under voltage protection: Default 1.5V(Adjustable)
    13>.Over temperature protection: About 80℃(Unadjustable)
    14>.Fan speed: 8000RPM+/-10%
    15>.Size: 79*43*56mm
 
4.Function:
    1>.Display current A, voltage V, power W, capacity Ah and Discharge time
    2>.Automatically count discharge capacity and discharge time
    3>.Supports setting maximum discharge capacity (OAH) and maximum discharge time (OHP). (Achieve unattended for power aging test)
    4>.Intelligent temperature control fan.The fan automatically starts when the power is greater than 10W or the temperature is greater than 40℃
    5>.Rotary coded potentiometer for precise current adjustment to 0.01A
    6>.The current can be locked to prevent misoperation
    7>.Data group function:user can choose whether to accumulate the capacity value and running time of the previous phase
    8>.Support UART data communication
 
5. Discharge capacity and discharge time statistics:
    1>.Discharge capacity statistics:FZ35 start to statistics when load current is not zero. After the next load current is zero, it is considered that a discharge process is completed and the statistics are over.
 
  2>.Discharge time statistics: FZ35 start to statistics when load current is not zero. After the next load current is zero, it is considered that a discharge process is completed and the statistics are over.
 
6.Set OAH and OHP:
    1>.Set maximum capacity OAH:FZ35 automatically stops working and flashes "OAH" on screen when the load discharge capacity is higher than the set maximum capacity after enable OAH function.The capacity statistics are automatically cleared after the OAH alarm is released.
 
    2>.Set maximum discharge time OHP:FZ35 automatically stops working and flashes "OHP" on screen when the load discharge time is more than the set maximum discharge time after enable OHP function.The discharge time statistics are cleared  automatically after the OHP alarm is released.
 
    3>.The OAH and OHP can be perfectly implemented unattended for power aging test.
 
    4>.FZ35 will record discharge capacity and discharge time even if OAH and OHP are not enable.But FZ35 stops working after reaching the set value if OAH and OHP are enable.The running time of the FZ35 is the countdown mode when enable OHP.
 
7.Using steps:
    1>.Connect to work voltage at ‘V+’ and ‘V-’.
    2>.Set right parameters as set manual. 
    3>.Remove work voltage and connect load.
    4>.Re-power.Test and use.
 
8.Note:
    1>.It can not output voltage. User need connect load power supply for load.
    2>.Please read use manual and description before use.
 
9. PDF User Manual:
 
 

1.Tested by ICStation's Outstanding Partner:

Learn More Details in the Video:
(The language in the video is English)

2. Tested by ICStation's Outstanding Partner Treicer100:

Learn More Details in the Video:
(The language in the video is Russian)

3. Tested by ICStation's Outstanding Customer Rolf:

(The language in the video is German)

 

4. Tested by ICStation's Outstanding Partner:

(The language in the video is Russian)

Customer Reviews (0)

Move to