1.Description:
YL-003 is a Battery Voltage Detector with relay output controller switch. Its working voltage and measured voltage are separated independently which is convenient for users to quickly change different batteries.

Its work voltage is DC 5V and can measure batteries up to 55V. It can set the Upper Limit Voltage Value and the Lower Limit Voltage Value. Then choose different working modes to meet different applications.
 

2.Features:
    1>.Independent measured voltage and working voltage
    2>.High-precision 12-bit AD resolution
    3>.6-Kinds work mode adjustable
    4>.Relay switch output
    5>.High sensitivity
    6>.Automatic level control

 

3.Parameters:
    1>.Product Name:YL-003 Battery Voltage Detector
    2>.Product Number:YL-003
    3>.Working Voltage:DC 5V
    4>.Measured Voltage:DC 0.00-55.0V
    5>.Output Type:Relay Switch Output(Not voltage output!)
    6>.Set Method:Button Set
    7>.Display: 3Bit Red LED Display Screen
    8>.Measurement Accuracy:12Bit ADC
    9>.Working Temperature range:-20℃~85℃
    10>.Working Humidity Range:5%-100%RH
    11>.Module Size:68*28*20mm

 

4.Button Set:
    1>.K1 Button:
        1.1>.Press to adjust selected bit. 
        1.2>.Keep press more than 2second to turn ON or OFF display screen.
    2>.K2 Button:
        2.1>.Press to increase parameter value for selected bit at parameter value set status.(Note: The value just be increase for 0 to 9 in turns.But can not decrease.)
        2.2>.Keep press more than 0.5second to set work mode P-1 to P-6.
    3>.Display screen will flashing at parameter set status.
    4>.Module will save parameters and return to normal display status and screen stop flashing without any operation for button within 2second.

 

5.Set Method:
1>.Set the Lower Limit Voltage Value:
Press K1 Button at the first time:The first bit will flashing.It is used to adjust the highest bit for the Lower Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

Press K1 Button at the second time:The second bit will flashing.It is used to adjust the middle bit for the Lower Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

Press K1 Button at the third time:The third bit will flashing.It is used to adjust the lowest bit for the Lower Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

2>.Set the Upper Limit Voltage Value:
Press K1 Button at the fourth time:The first bit will flashing.It is used to adjust the highest bit for the Upper Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

Press K1 Button at the fifth time:The second bit will flashing.It is used to adjust the middle bit for the Upper Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

Press K1 Button at the sixth time:The third bit will flashing.It is used to adjust the lowest bit for the Upper Limit Voltage Value.Then press K2 button to set value for 0~9.Please set next bit within 2second!

3>.Press K1 Button at the seventh time to save parameters and return to normal display status and display measured voltage.
 

4>.Select Work Mode:
4.1>.Keep press more than 0.5second to set work mode P-1 to P-6.

4.2>.P-1:Charge monitoring mode.
Relay turn ON when the Measured Voltage Value is less than the Lower Limit Voltage Value (It is used to turn ON charger for battery and start charging).

Relay turn OFF when the Measured Voltage Value is more than the Upper Limit Voltage Value(It is used to turn OFF charger for battery and stop charging)

4.3>.P-2:Discharge monitoring mode.
Relay turn ON when the Measured Voltage Value is more than the Upper Limit Voltage Value(It is used to turn ON discharge for battery and start discharge).

Relay turn OFF when the Measured Voltage Value is less than the Lower Limit Voltage Value(It is used to turn OFF discharge for battery and stop discharge).

4.4>.P-3:Turn ON out of range.
Relay turn OFF when the Measured Voltage Value output of range that between the Lower Limit Voltage Value and the Upper Limit Voltage Value. Otherwise relay will keep ON.

4.5>.P-4:Turn ON within range.
Relay turn ON when the Measured Voltage Value between the Lower Limit Voltage Value and the Upper Limit Voltage Value. Otherwise relay will keep OFF.

4.6>.P-5:High voltage detection.
Relay turn ON when the Measured Voltage Value is more than the Lower Limit Voltage Value.
Relay turn OFF when the Measured Voltage Value is less than the Lower Limit Voltage Value.

4.7>.P-6:High voltage detection.
Relay turn ON when the Measured Voltage Value is less than the Lower Limit Voltage Value.
Relay turn OFF when the Measured Voltage Value is more than the Lower Limit Voltage Value.

 

6.Note:
    1>.It is a relay switch output so it can not output voltage!
    2>.It needs three voltage:work voltage,measured voltage,load voltage.
    3>.Please read use manual and description before use.

 

7.Application:
    1>.Battery detector
    2>.Electric car
    3>.Electric bicycle
    4>.Outdoor mobile equipment

 

8.Package:
    1pcs YL-003 Battery Voltage Detector

There are currently no product reviews.

First we should say that ICStation doesn't accept any form of pay on delivery.Items used to be shipped after receiving the order info and payment.

1) Paypal Payment

PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account). 



We are PayPal Verified 

 

2) West Union


 

We know that some of you do not have the Paypal account. 

But please take it easy. You can use West Union payment method.
Learn more at West Union at www.westernunion.com.
 
For the receiver info, please contact us at orders@icstation.com.
 
3) Bank Transfer / Wire Transfer / T/T
 

Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$500. The bank will charge about US$60 for the transfer fee if we do the payment in these ways. 

For other payment method, please contact us at orders@icstation.com for more details.

1. Hongkong / Sinapore Airmail

(1) Due to the high risk of package lost recently, we have to stop using the free shipping way these days. Hope for your kind understanding! And the $3 is for tracking number and delivery insurance ^0^ Enjoy order from us. 

Free Shipping for all orders over $20 ^0^ (with free tracking number and delivery insurance fee)

(2) Shipping time 
Shipping time is 7-20 business days to most of countries; please view below table for exactly shipping time to your location. 

7-15 working days to: Most of Asia countries
10-16 working days to: USA , Canada , Australia , UK , Most of Europe countries
13-20 working days to: Germany , Russia
18-25 working days to: France , Italy , Spain , South Africa
20-45 working days to: Brazil , Most of South America countries

2. EMS/DHL/UPS Express

(1)Shipping Fee: Free for the order which meet the following requirements
Total price of the order >= 200USD or Total weight of the order >= 2.2KG

When the order meets to one of the above requirement, it will be shipped for FREE via EMS/DHL/UPS Express to below country. 
Asia: Japan , South Korea , Mongolia . Malaysia , Singapore , Thailand , Vietnam , Cambodia , Indonesia , Philippines 
Oceania: Australia , New Zealand , Papua New Guinea 
Europe& America: Belgium, Britain, Denmark, Finland, Greece, Ireland, Italy, Luxembourg, Malta, Norway, Portugal, Switzerland, Germany, Sweden, France, Spain, USA, Austria, Canada
Note: Shipping Fee to other countries, please contact orders@ICStation.com

(2) Shipping Time
Shipping time is 3-5 working day (about 1 week) to most of countries. 

Because the package would be returned to the sender if it had not been signed by the receiver in 2-3 day (DHL) or 1 week (EMS,) or 2 weeks (Registered Email), please pay attention to the arriving time of the package. 

Note:

1) APO and PO Box Addresses

We strongly recommend that you provide a physical address for order delivery. 
Because that DHL and FedEx are unable to deliver items to APO or PO BOX addresses. 
 
2) Contact Phone Number
Receivers' contact phone number is required by express shipping agency for the package delivery. Please provide us with your latest phone number.


3. Note
1) Delivery Time of mixed orders with items in different Shipping Status should be calculated using the longest estimate times listed. 
2) Chinese Holiday Reminder: During annual Chinese holidays, services from certain suppliers and carriers may be affected, and delivery for orders placed around the following times may be delayed by 3 - 7 days: Chinese New Year; Chinese National Day,etc. 
3) Once your order is shipped, you will receive an email notification from icstation.com
4) Track the order which with tracking number via below links:

Registered Airmail: www.17track.net/en

Your Recent History