Home > Relay Module > Function Relay Module > DC 12V 0-5A Current Detector Current Switch Relay Controller Module AC/DC Current Monitor LED Display Adjustable Work Mode

DC 12V 0-5A Current Detector Current Switch Relay Controller Module AC/DC Current Monitor LED Display Adjustable Work Mode

GY18313
5 9
$16.99
Contact us for wholesale price
- OR - - OR - Add to Wish List

1.Description:
    YLV-2 is a AC/DC Current Detector Module with relay output controller switch. Its working voltage and measured current are separated independently which is convenient for users to quickly change different measured current.

  Its work voltage is DC 12V and can measure 0-5A AC/DC current. It can set the Upper Limit Current Value and the Lower Limit Current Value. Then choose different working modes to meet different applications.

2.Features:
    1>.Independent measured voltage and working voltage
    2>.High-precision resolution
    3>.6-Kinds work mode adjustable
    4>.Relay switch output
    5>.Support AC and DC current measure
    6>.Parameter memory function

3.Parameters:
    1>.Product Name:YLV-2 AC/DC Current Detector Module
    2>.Product Number:YLV-2
    3>.Working Voltage:DC 12V
    4>.Measured Current:0.00A-5.00A
    5>.Output Type:Relay Switch Output(Not voltage output!)
    6>.Set Method:Button Set
    7>.Display: 3Bit Red LED Display Screen
    9>.Working Temperature range:-20℃~85℃
    10>.Working Humidity Range:5%-100%RH
    11>.Module Size:64*35*16mm

4.Button Set:
    1>.K1 Button:
        1.1>.Keep press more than 3second enter into parameter set mode.
        1.2>.Press to set work mode P-1 to P-6 at parameter set mode.
    2>.K2 Button:
        2.1>.Press to adjust selected bit. 
    3>.K3 Button:
        3.1>.Press to turn ON or OFF display screen at normal display mode.
        3.2>.Press to increase parameter value for selected bit at parameter value set status.(Note: The value just be increase for 0 to 9 in turns.But can not decrease.)

5.Set Method:
    1>.Set the Lower Limit Current Value:
        1.1>.Press K2 Button at the first time:The first bit will flashing.It is used to adjust the highest bit for the Lower Limit Current Value.Then press K3 button to set value for 0~9.
        1.2>.Press K2 Button at the second time:The second bit will flashing.It is used to adjust the middle bit for the Lower Limit Current Value.Then press K3 button to set value for 0~9.
        1.3>.Press K2 Button at the third time:The third bit will flashing.It is used to adjust the lowest bit for the Lower Limit Current Value.Then press K3 button to set value for 0~9.
    2>.Set the Upper Limit Current Value:
        2.1>.Press K2 Button at the fourth time:The first bit will flashing.It is used to adjust the highest bit for the Upper Limit Current Value.Then press K3 button to set value for 0~9
        2.2>.Press K2 Button at the fifth time:The second bit will flashing.It is used to adjust the middle bit for the Upper Limit Current Value.Then press K3 button to set value for 0~9.
        2.3>.Press K2 Button at the sixth time:The third bit will flashing.It is used to adjust the lowest bit for the Upper Limit Current Value.Then press K3 button to set value for 0~9.
    3>.Press K2 Button at the seventh time to adjust the calibration value.Then press K3 button to set value.
    4>.Press K2 Button at the eighth time to save parameters and return to normal display status and display measured current.
    5>.Select Work Mode:
        5.1>.Keep press K1 button more than 3second enter into parameter set mode.
        5.2>.Press K1 button to set work mode P-1 to P-6 at parameter set mode.
        5.3>.P-1:Relay turn ON and then OFF after 1second if the Measured Current is more than then the Lower Limit Current Value.
        5.4>.P-2:Relay turn ON and keep ON if the Measured Current is more than then the Lower Limit Current Value.
        5.5>.P-3:Turn ON within range.
            5.5.1>.Relay turn ON when the Measured Current Value between the Lower Limit Current Value and the Upper Limit Current Value. Otherwise relay will keep OFF.
        5.6>.P-4:Turn ON out of range.
           5.6.1>.Relay turn OFF when the Measured Current Value output of range that between the Lower Limit Current Value and the Upper Limit Current Value. Otherwise relay will keep ON.
    5.7>.P-5:High current detection.
        5.7.1>.Relay turn ON when the Measured Current Value is less than the Lower Limit Voltage Value.
        5.7.2>.Relay turn OFF when the Measured Voltage Value is more than the Upper Limit Voltage Value.
    5.8>.P-6:High current detection.
        5.8.1>.Relay turn ON when the Measured Voltage Value is more than the Upper Limit Voltage Value.
        5.8.2>.Relay turn OFF when the Measured Voltage Value is less than the Lower Limit Voltage Value.

6.Note:
    1>.It is a relay switch output so it can not output voltage!
    2>.It needs three voltage:work voltage,measured voltage,load voltage.
    3>.Please read use manual and description before use.

7.Application:
    1>.Battery detector
    2>.Electric car
    3>.Electric bicycle
    4>.Outdoor mobile equipment

 

8.Package:
1pcs YLV-2 YLV-2 AC/DC Current Detector Module

There are currently no product reviews.

First we should say that ICStation doesn't accept any form of pay on delivery.Items used to be shipped after receiving the order info and payment.

1) Paypal Payment

PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account). 



We are PayPal Verified 

 

2) West Union


 

We know that some of you do not have the Paypal account. 

But please take it easy. You can use West Union payment method.
Learn more at West Union at www.westernunion.com.
 
For the receiver info, please contact us at orders@icstation.com.
 
3) Bank Transfer / Wire Transfer / T/T
 

Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$500. The bank will charge about US$60 for the transfer fee if we do the payment in these ways. 

For other payment method, please contact us at orders@icstation.com for more details.

1. Hongkong / Sinapore Airmail

(1) Due to the high risk of package lost recently, we have to stop using the free shipping way these days. Hope for your kind understanding! And the $3 is for tracking number and delivery insurance ^0^ Enjoy order from us. 

Free Shipping for all orders over $20 ^0^ (with free tracking number and delivery insurance fee)

(2) Shipping time 
Shipping time is 7-20 business days to most of countries; please view below table for exactly shipping time to your location. 

7-15 working days to: Most of Asia countries
10-16 working days to: USA , Canada , Australia , UK , Most of Europe countries
13-20 working days to: Germany , Russia
18-25 working days to: France , Italy , Spain , South Africa
20-45 working days to: Brazil , Most of South America countries

2. EMS/DHL/UPS Express

(1)Shipping Fee: Free for the order which meet the following requirements
Total price of the order >= 200USD or Total weight of the order >= 2.2KG

When the order meets to one of the above requirement, it will be shipped for FREE via EMS/DHL/UPS Express to below country. 
Asia: Japan , South Korea , Mongolia . Malaysia , Singapore , Thailand , Vietnam , Cambodia , Indonesia , Philippines 
Oceania: Australia , New Zealand , Papua New Guinea 
Europe& America: Belgium, Britain, Denmark, Finland, Greece, Ireland, Italy, Luxembourg, Malta, Norway, Portugal, Switzerland, Germany, Sweden, France, Spain, USA, Austria, Canada
Note: Shipping Fee to other countries, please contact orders@ICStation.com

(2) Shipping Time
Shipping time is 3-5 working day (about 1 week) to most of countries. 

Because the package would be returned to the sender if it had not been signed by the receiver in 2-3 day (DHL) or 1 week (EMS,) or 2 weeks (Registered Email), please pay attention to the arriving time of the package. 

Note:

1) APO and PO Box Addresses

We strongly recommend that you provide a physical address for order delivery. 
Because that DHL and FedEx are unable to deliver items to APO or PO BOX addresses. 
 
2) Contact Phone Number
Receivers' contact phone number is required by express shipping agency for the package delivery. Please provide us with your latest phone number.


3. Note
1) Delivery Time of mixed orders with items in different Shipping Status should be calculated using the longest estimate times listed. 
2) Chinese Holiday Reminder: During annual Chinese holidays, services from certain suppliers and carriers may be affected, and delivery for orders placed around the following times may be delayed by 3 - 7 days: Chinese New Year; Chinese National Day,etc. 
3) Once your order is shipped, you will receive an email notification from icstation.com
4) Track the order which with tracking number via below links:

Registered Airmail: www.17track.net/en

Your Recent History