Home > Sensor Module > Temperature Module > SHT20 Humidity Temperature Controller DC 12V 0-100%RH -20-60 Celsius Digital LCD Display 2-Channel Relay Module

SHT20 Humidity Temperature Controller DC 12V 0-100%RH -20-60 Celsius Digital LCD Display 2-Channel Relay Module

13319
5 9
$16.99 $11.89
Contact us for wholesale price
Time Remaining:
- OR - - OR - Add to Wish List

Description:
XY-TR01 Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel.
Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor.

Features:
1>. Support UART;
2>. LCD high definition display;
3>. Support measurement temperature and humidity at the same time;
4>. Support Micro USB input;
5>. Working mode is automatically adjusted;
6>. High precision detection.

Parameters:
1>. Product name: Humidity Temperature Controller;
2>. Model: XY-TR01;
3>. Temperature range: -20℃~60℃;
4>. Humidity range: 0%-100%RH;
5>. Control precision: 0.1℃ & 0.1%RH;
6>. Output type: Relay output;
7>. Rated load: 10A(MAX);
8>. Size of Controller: 60*58*22mm
9>. Size of Sensor probe: 60*30*20mm
10>. Length of Sensor cable: 1meter

Temperature Function:
1>. Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Temperature and Stop Temperature.
Start Temperature is more than stop temperature, Turn ON cooling mode 'C'.
Start temperature is less than stop temperature, Turn ON heating mode 'H'.

2>. Cooling Mode 'C':
Relay turn ON and Red Indicator turn ON and Refrigeration equipment starts working if connect load when Current Temperature is more than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Refrigeration equipment stops working if connect load when Current Temperature is less than Stop Temperature.

3>. Heating mode 'H':
Relay turn ON and Red Indicator turn ON and Heating equipment starts working if connect load when Current Temperature is less than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Heating equipment stops working if connect load when Current Temperature is more than Stop Temperature.

4>. Temperature Correction ‘ OFE ’(-10.0~10.0℃):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Temperature = Measured Temperature + Calibration Value.
Setting method:
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’.
4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.

5>. Set Start/Stop Temperature:
Keep press button 'TM+' for 3second in the normal running interface into Start Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'TM-' for 3second in the normal running interface into Stop Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.

6>. Relay enable (default on):
Short press button ‘TM-’ in the normal running interface.Turn ON or OFF temperature relay output enable.Screen will display ‘℃’ and flashes if If the temperature relay is OFF.

Humidity Function:
1>. Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Humidity and Stop Humidity.
Start Humidity is more than stop Humidity, Turn ON dehumidification mode 'd'.
Start Humidity is less than stop Humidity, Turn ON humidification mode 'E'.

2>. Dehumidification Mode 'd':
Relay turn ON and Green Indicator turn ON and Dehumidification equipment starts working if connect load when Current Humidity is more than Start Humidity.
Relay turn OFF and RED Indicator turn OFF and Dehumidification equipment stops working if connect load when Current Humidity is less than Stop Humidity.

3>. Humidification mode 'E':
Relay turn ON and Green Indicator turn ON and Humidification equipment starts working if connect load when Current Humidity is less than Start Humidity.
Relay turn OFF and Green Indicator turn OFF and Humidification equipment stops working if connect load when Current Humidity is more than Stop Humidity.

4>.Humidity Correction ‘ RH ’(-10.0~10.0%RH):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Humidity= Measured Humidity+ Calibration Value.
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’.
4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.

5>.Set Start/Stop Humidity:
Keep press button 'RH+' for 3second in the normal running interface into Start Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'RH-' for 3second in the normal running interface into Stop Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.

6>.Relay enable (default on):
Short press button ‘RH-’ in the normal running interface.Turn ON or OFF humidity relay output enable.Screen will display ‘%’ and flashes if If the temperature relay is OFF.

Using Steps:
1>. Connect sensor to controller;
2>. Connect to power supply to controller;
3>. Adjust Start Temperature, Stop temperature and Temperature Correction;
4>. Adjust Start Humidity, Stop Humidity and Humidity Correction;
5>. Enable relay output according requirement;
6>. Remove power supply;
7>. Connect to load with power supply at relay output terminal if need at Step5;
8>. Connect to power supply for controller again;
9>. Test and working!

Additional Features:
1>. Set or read data by UART.
Parameters such as start temperature/humidity, stop temperature/humidity, temperature/humidity correction, etc. can be set through the UART.

2>. Temperature/Humidity real-time reporting.
The controller module will report the current temperature/humidity to the terminal equipment by the UART at intervals of 1 second to facilitate data acquisition if the temperature/humidity reporting function is turned ON.

3>. Relay enable (default on).
If the relay enable is turned off, the relay remains off.
That is, the output state will never change, no matter what the measured temperature/humidity is.

UART Communication and Parameter Settings:
The system supports UART data upload and parameter setting functions (TTL level);
UART: 9600, 8, 1

NO. Command Function
1 Start Start test value report
2 Stop Stop test value report
3 Read Read setting parameters
4 T:ON Temperature Relay enable ON
5 T:OFF Temperature Relay enable OFF
6 H:ON Humidity Relay enable ON
7 H:OFF Humidity Relay enable OFF
8 TS:XX.X Set Start Temperature Value (-20.0~60.0℃)
9 TP:XX.X Set Stop Temperature Value (-20.0~60.0℃)
10 HS:XX.X Set Start Humidity Value (00.0%~100.0%RH)
11 HP:XX.X Set Stop Humidity Value (00.0%~100.0%RH)
12 TC:XX.X Temperature calibration (-10.0~10.0℃)
13 HC:XX.X Humidity calibration (-10.0~10.0%RH)

Temperature and humidity data upload format:
Temperature format: work mode (H/C), Current Temperature, Temperature relay status;
Humidity format: work mode (E/D), Current Humidity, Humidity relay status;
For example:
H, 20.5℃, CL: Heating Mode, Current Temperature 20.5℃, Temperature relay is OFF.
D, 50.4%,OP: Dehumidification mode, Current Humidity 50.4%RH, Humidity relay is ON.

Application:
1>. Control cabinet;
2>. Production workshop;
3>. Hatching aquaculture control;
4>. Tobacco industry;
5>. Printing house;
6>. Aquarium temperature control;
7>. Bedroom.

Note:
1>. It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power supply.

Package:
1>. 1pcs XY-TR01 Humidity Temperature Controller;
2>. 1pcs XY-MD01 SHT20 Sensor;
3>. 4pcs White isolation seat.

Product Details:






 

There are currently no product reviews.

ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:

1) Paypal Payment

PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account). 



We are PayPal Verified 

 

2)  Bank Transfer / Wire Transfer / T/T

 

Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.

For other payment method, please contact us at orders@icstation-team.com for more details.

Customers who bought this product also purchased

AC-DC 90V-265V to 12V 8A 100W Voltage Converter Switching Power Supply Module Buck Step Down Module
$10.21
$14.59
31
DC 12V Photosensitive Sensor Controller Relay Driver Waterproof Brightness Adjustable Switch
$4.87
$6.95
30
DC 4-28V Red+Blue Fahrenheit Dual Display Digital Thermometer with 2 NTC Waterproof Metal Probes Temperature Sensor
$8.11
$11.59
31
IP67 Non-Contact Liquid Level Sensor High/Low Signal Output Waterproof Water Level Detector
$4.89
$6.99
31
Red Display Lithium Battery Capacity Indicator Voltmeter ON/OFF Controller Voltage Tester 12.6V for 12V Lead-acid Battery or 4pcs 3.7V 4.2V Lithium Batteries
$4.19
$5.99
31
DC 12V 1 Channel Relay Module High Low Level Adjustable Trigger Board Optocoupler Isolated Output
$2.37
$3.29

Sold Out

29
DC to DC High Power Step Down Buck Converter Adjustable Power Supply Module 12A DC 5-40V to DC 1.2-36V
$6.29
$8.99
30
XH-M604 Charge Control Module DC 6-60V Battery Protection Board Controller for Lithium/Lead-acid Battery Solar Panel
$7.69
$10.99
31
125Khz EM4100 ID Reader RFID Reader Module UART Output Access Control System for Arduino
$5.59
$7.99
31
DC-DC SX1308 Converter Step-UP Power Module Adjustable Booster Converter
$0.88
$1.25
30
Universal Adjustable DC to DC Step Down Power Supply Module Buck Converter DC 5-16V to DC 1.25V/1.5V/1.8V/2.5V/3.3V/5V
$1.11
$1.59
31

Your Recent History

SHT20 Humidity Temperature Controller DC 12V 0-100%RH -20-60 Celsius Digital LCD Display 2-Channel Relay Module
$11.89
$16.99
30